FDA data integrity guidance: the 2018 Q&A, question by question
Published 18 min read
Fig. 01FDA's data integrity guidance is the guidance for industry “Data Integrity and Compliance With Drug CGMP: Questions and Answers”, final since December 2018. It covers drug manufacturing under 21 CFR parts 210, 211 and 212, biologics included, and answers 18 questions, from what an audit trail is to how FDA expects a data integrity problem to be fixed. Below: which document you need, every question with the rules FDA's answer cites, and what each asks a QC lab or a quality unit to do.
Which FDA guidance on data integrity you mean
The guidance has one current version. FDA published a draft in April 2016 under the title “Data Integrity and Compliance With CGMP”, revised it after comments, and announced the final guidance in the Federal Register on December 13, 2018 (83 FR 64132). FDA's guidance list, read on 2026-10-28, still shows the December 2018 text as the final one: searches for a 2020 or 2022 edition find the same document. One newer FDA guidance carries data integrity in its title, a draft for bioavailability and bioequivalence studies.
Scroll sideways for every column
| Document | Status | Who it covers | When you need it |
|---|---|---|---|
| Data Integrity and Compliance With Drug CGMP: Questions and Answers | Final, December 2018. Draft April 2016, titled “Data Integrity and Compliance With CGMP” | Drug CGMP under 21 CFR parts 210, 211 and 212, biologics included; issued by CDER, CBER and CVM | The one most people mean. Walked question by question on this page |
| Data Integrity for In Vivo Bioavailability and Bioequivalence Studies | Draft, April 2024. FDA marks it “Not for implementation” | Clinical and bioanalytical parts of BA and BE studies behind INDs, NDAs and ANDAs, and some CDER biologics applications | Read it if you run or sponsor BA or BE studies; it has not been finalized |
| Part 11, Electronic Records; Electronic Signatures: Scope and Application | Final, 2003 | Electronic records and signatures under 21 CFR Part 11, across FDA-regulated products | The 2018 Q&A points to it for Part 11. See what Part 11 is |
| Electronic Systems, Electronic Records, and Electronic Signatures in Clinical Investigations: Q&A | Final, October 2024 | Sponsors, investigators, IRBs and CROs in clinical investigations | The clinical-side companion; covers cloud and IT service providers |
Status and dates as FDA's guidance list showed them on 2026-10-28.
Guidance, not regulation
Each page of the Q&A carries “Contains Nonbinding Recommendations”, and FDA says its “should” means “suggested or recommended, but not required.” But most answers cite a section of Part 211. Where it does, the duty comes from the regulation, which binds whether or not you follow the guidance.
Takeaway
When an audit report, a quality agreement or an SOP cites “FDA data integrity guidance”, read it as the December 2018 drug CGMP Q&A unless it names the BA/BE draft. Cite it by full title and date, and trace each commitment to the Part 211 section the answer names.
What the 2018 guidance covers
FDA states its purpose as “to clarify the role of data integrity in current good manufacturing practice (CGMP) for drugs, as required in 21 CFR parts 210, 211, and 212.” CGMP there includes biologics, and for active pharmaceutical ingredients FDA says its requirements are consistent with ICH Q7. It was not written for device makers, GLP studies or clinical trials, which have their own texts; the overview of GxP sorts out which applies to you.
FDA gives its reason in the background section: “In recent years, FDA has increasingly observed CGMP violations involving data integrity during CGMP inspections,” and those violations “have led to numerous regulatory actions, including warning letters, import alerts, and consent decrees.” It gives no count there, and neither do we. The approach it asks for is risk-based: firms should have “meaningful and effective strategies” built on their process understanding, with management involved.
Electronic records and signatures sit beside it, not inside it. The Q&A says those requirements “are laid out in 21 CFR part 11” and points to the 2003 Scope and Application guidance; whether a given record falls under Part 11 is what the Part 11 applicability checker answers, and what 21 CFR Part 11 is and who it binds covers the rule.
Takeaway
FDA's background lists seven questions to ask of any record, from “Are activities attributable to a specific individual?” to whether data is kept through its retention period. They make a usable gap-assessment frame; the sheet at the foot of this page maps each to the answers that address it.
All 18 questions on one sheet
The guidance numbers its questions 1 to 18, with question 1 split into six definitions. Filter by area, or read straight down. Each number links to the part of this page that walks its area.
18 of 18 questions shown
Scroll sideways for all columns
| Q | FDA asks | FDA's answer, short | Rules the answer cites |
|---|---|---|---|
| 1.a | What is data integrity? | Completeness, consistency and accuracy of data, which should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate (ALCOA). | Footnote 5: § 211.100(b), § 211.101(d), § 211.180, § 211.194(a) and others |
| 1.b | What is metadata? | “The contextual information required to understand data”, kept with the data for the whole retention period. | § 211.188, § 211.194 |
| 1.c | What is an audit trail? | A secure, computer-generated, time-stamped record that lets you rebuild who created, changed or deleted a record, and when. | § 211.68, § 211.100, § 211.160(a), § 211.188, § 211.194 |
| 1.d | Static and dynamic records | Static is fixed (paper, an image); dynamic lets the user interact with the content, such as reprocessing a chromatogram. | None named in the answer |
| 1.e | What “backup” means in § 211.68(b) | A true copy kept securely for the whole retention period; a temporary crash copy does not count. | § 211.68(b), § 211.180 |
| 1.f | The “systems” in § 211.68 | Hardware, software, peripherals, networks, cloud infrastructure, personnel and the documents that go with them. | § 211.68 |
| 2 | When may a CGMP result be invalidated? | Only with a valid, documented, scientifically sound justification; the invalidated data stays in the batch record with the investigation. | § 211.160(b), § 211.188, § 211.192 |
| 3 | Does each CGMP workflow need validation? | Yes. Qualifying the platform is not enough; validate each workflow for its intended use, scaled to risk. | § 211.63, § 211.68(b), § 211.110(a) |
| 4 | How should access be restricted? | Only authorized people change records; system administrators are independent of the record content; keep a list of who has access. | § 211.68(b) |
| 5 | Why are shared logins a problem? | A shared login cannot identify one person, so the system does not conform to parts 211 and 212. | § 211.68(b), § 211.188(b)(11), § 211.194(a)(7), (8) |
| 6 | How should blank forms be controlled? | Issued and reconciled by the quality unit or another document control method; spoiled forms stay in the record. | § 211.100, § 211.160(a), § 211.186, § 211.192 |
| 7 | Who should review audit trails? | Whoever reviews the record reviews its audit trail with it; the quality unit approves. | § 211.22(a), § 211.192, § 211.194(a)(8) |
| 8 | How often should audit trails be reviewed? | As often as the rule says the data is reviewed; where it is silent, set the frequency by risk assessment. | § 211.188(b), § 211.22 |
| 9 | Can electronic copies be true copies? | Yes, if they keep the content, the meaning, all metadata and the static or dynamic nature of the original. | § 211.180(d) |
| 10 | Printouts instead of instrument files? | A printout from a pH meter or balance can be the original; a dynamic file such as an FT-IR spectrum cannot be replaced by one. | § 211.180(d), § 211.194(a)(8) |
| 11 | E-signatures on master production and control records? | Yes, with appropriate controls, even where § 211.186(a) says “full signature, handwritten”. | § 211.186(a), § 11.2(a) |
| 12 | When does electronic data become a CGMP record? | When it is generated to satisfy a CGMP requirement. Save at each step or injection, not at the end of the set. | § 211.100(b), § 211.160(a), § 211.180(d) |
| 13 | Actual samples in system suitability runs? | Using an actual sample to disguise testing into compliance is violative; if an actual sample is used, it should be a characterized secondary standard from another batch. | § 211.160, § 211.165, § 211.192 |
| 14 | Only the final reprocessed chromatography result? | No. Reprocessing follows a written procedure and every result is kept for review. | § 211.160, § 211.165(c), § 211.194(a)(4) |
| 15 | Can an internal tip be handled informally? | No. Suspected falsification is investigated inside the CGMP quality system, whoever raised it. | § 211.22(a), § 211.192, § 211.198 |
| 16 | Should training cover data integrity? | Yes, as part of routine CGMP training. | § 211.25 |
| 17 | Can FDA look at electronic records? | Yes, every CGMP record, including emails that support CGMP work, such as one authorizing batch release. | § 211.180(c) |
| 18 | How should problems be addressed? | Find the scope and root cause, assess the risk, and run a global corrective action plan. | None; mirrors the Application Integrity Policy |
Questions shortened from FDA's wording; answers are our one-line reading of the December 2018 text, read 2026-10-28. The cites column lists sections FDA's answer names, not every rule that applies.
Fig. 02The six terms FDA defines (Q1)
Question 1 is a glossary, and the rest of the guidance leans on it. Two of its terms have pages of their own here; the other four are short enough to take in one pass.
Data integrity. “The completeness, consistency, and accuracy of data”, where complete, consistent and accurate data is attributable, legible, contemporaneously recorded, original or a true copy, and accurate: ALCOA. FDA stops at those five. The four extra attributes most quality manuals carry come from PIC/S, and the ALCOA+ principles of data integrity page shows each one on paper, in a system and in a spreadsheet. FDA's footnote ties each attribute to sections of parts 211 and 212, so ALCOA here sums up rules that already exist rather than adding a new one.
Metadata and audit trail. Metadata is the context that makes a value mean something, and the audit trail is the record of every create, change and delete. FDA wants both kept with the data for the whole retention period, with the link between data and metadata “preserved in a secure and traceable manner”. What a trail must hold, and how to tell metadata from trail, is set out in what an audit trail is in GxP.
Static and dynamic. A static record is fixed, like paper or an image. A dynamic one lets the user interact with it: FDA's examples are a chromatogram whose baseline can be moved and reprocessed, and a spreadsheet whose formulas can be edited. The difference decides Q9 and Q10 below, and it is why a spreadsheet that computes a result is a record to control, not a calculator (see Excel spreadsheets under Part 11).
Backup. In § 211.68(b), a backup is “a true copy of the original record that is maintained securely throughout the record retention period”, with its metadata, in the original format or one compatible with it. A temporary copy made in case of a crash does not count. FDA notes this is what its software validation guidance calls an archive.
Systems. The “computer or related systems” of § 211.68 are wider than the software: hardware, peripherals, networks, cloud infrastructure, personnel and documents such as user manuals and SOPs. A hosted system is still your system under this definition; the Part 11 guide to cloud and SaaS systems covers what to ask the vendor.
Lab data: invalidation, printouts and chromatography
Five answers are about what a QC lab keeps. Read together, they say one thing: every result produced to meet a CGMP requirement stays in the record, including the ones you would rather not report.
Q12, when data becomes a record. “When generated to satisfy a CGMP requirement, all data become a CGMP record.” Chromatographic data should be saved “upon completion of each step or injection”, not at the end of the injection set, and aborted or incomplete injections should be in the audit trail and investigated. Scrap paper that is thrown away after transcription is “not acceptable”. FDA names the fix for systems: a LIMS or an electronic batch record that saves after each entry, plus a procedure that data is keyed in when it is generated.
Q2, invalidating a result. A result can be left out of the batch decision only with “a valid, documented, scientifically sound justification”, and even then the batch record that goes to the quality unit holds the original data with the investigation report. FDA adds that paper and electronic records are “subject to the same requirements”.
Q14, reprocessing. Saving only the final reprocessed result is not acceptable. Reprocessing follows written procedures and “each result” is retained for review. FDA also says reprocessing “should not be regularly needed” for most analyses, so a method that is reprocessed often is worth investigating. The chromatography data system comparison reads vendors on exactly these controls.
Q10, printouts. A printout from a pH meter or a balance can be the original record, and then the printout or a true copy is kept. A dynamic file cannot be swapped for one: FDA's example is an FT-IR spectral file, which “is dynamic and can be reprocessed”, and a printout of it would not meet § 211.180(d). If the printout does not show the full spectrum, FDA adds, “contaminants may be excluded.” Both kinds of record get second-person review under § 211.194(a)(8).
Q13, system suitability. FDA has cited this in warning letters because, in some cases, actual samples run as “system suitability” tests have been “used as a means of testing into compliance”. If an actual sample is used, it should be a properly characterized secondary standard from a different batch than the samples being tested, under a written procedure.
Inspection risk
FDA: “All data—including obvious errors and failing, passing, and suspect data—must be in the CGMP records that are retained and subject to review and oversight.” Using an actual sample in test, prep or equilibration runs to disguise testing into compliance is, in FDA's words, “a violative practice”.
Takeaway
Pull one month of chromatography sequences. For each, check that aborted injections sit in the audit trail with a reason, that every reprocessed result is still on file, and that every invalidated result has a documented investigation in the batch record. Any gap is the place to start.
Systems and records: validation, access, copies and signatures
Nine answers are about the systems that hold CGMP data and the records they produce. Two of them, who reviews audit trails (Q7) and how often (Q8), are walked step by step in the audit trail review checklist; the rest are here.
Q3, validate the workflow. Each CGMP workflow is an intended use to check through validation, and “the extent of validation studies should be commensurate with the risk”. FDA's example: qualifying a manufacturing execution system shows the platform meets its specifications, but not that a master production and control record built in it carries the right calculations. That second proof is workflow validation. Where one system runs CGMP and non-CGMP work, assess how the second could affect the first. Computer system validation for small labs lays out the lifecycle that produces this evidence.
Q4 and Q5, access. Only authorized people may change records or enter lab data (§ 211.68(b)), and FDA recommends limiting by technical means where possible, through permissions rather than policy alone. The system administrator role “should be assigned to personnel independent from those responsible for the record content”, and each system needs a documented list of who holds which privileges. Shared logins fail because no one person can be identified (the audit trail failures table shows both settings in a lab); a shared read-only account is acceptable for viewing data, never for an action such as a second-person review that must be attributable to one person.
Q6, blank forms. Paper controls still count. FDA names bound, paginated notebooks stamped by document control as good practice, because a missing page or an unofficial notebook shows. Blank forms, electronic worksheets included, should be controlled by the quality unit or another document control method, issued in numbered sets and reconciled; a spoiled form stays in the record with the reason it was replaced.
Q9, electronic copies. An electronic copy is a true copy if it preserves “the content and meaning of the original record”, all the metadata needed to reconstruct the activity, and whether the original was static or dynamic. A dynamic record can be copied into another format only if a reader for that format is readily available.
Q11, electronic signatures. E-signatures with appropriate controls can replace handwritten signatures or initials “in any CGMP required record”, even where § 211.186(a) asks for a “full signature, handwritten”, because Part 11 (§ 11.2(a)) makes the controlled e-signature the equivalent. Firms should document the controls that identify who signed. The signature manifestation check tests what a signed record shows.
Q17, inspection. FDA may review every record required under CGMP, on paper or in a system, including electronic communications that support CGMP work. FDA's example is an email authorizing batch release. Copying electronic data for the inspector is part of allowing inspection (§ 211.180(c)).
Takeaway
For each CGMP system, write down three things: who holds administrator rights and whether any of them own data in it, which workflows were validated as used (not just installed), and how a true copy with metadata is produced for an inspector. Where the software itself cannot lock records or keep an edit trail, the data integrity software comparison reads the tools built for it.
Fig. 03People and remediation: tips, training and fixing a finding
The guidance opens with management, not software: it is “the role of management with executive responsibility to create a quality culture” in which staff see data integrity as a core value and report issues promptly. Three answers put that into practice.
Q15, internal tips. Suspected or known falsification is investigated under the CGMP quality system, “regardless of intent or how or from whom the information was received”, to find its effect on patients, product and data reliability, its root cause and the corrective actions. A quiet word with the analyst does not close it.
Q16, training. Training people to prevent and detect data integrity issues belongs in routine CGMP training, under the personnel rule § 211.25. A training record per SOP is where that shows.
Q18, remediation. When problems are found, FDA wants to see an investigation of their scope and root causes, “a scientifically sound risk assessment” of their effects, including on data used in submissions, and a management strategy with “a global corrective action plan that addresses the root causes”. FDA lists what that may include: a third-party auditor, removing the people responsible from positions where they can influence CGMP or application data, better quality oversight and computer systems, an anonymous reporting system, and data governance officials and guidelines. FDA says these expectations mirror its Application Integrity Policy.
Global means global
Q18 asks for a corrective action plan that addresses root causes, not the one instrument an inspector looked at. A remediation that fixes the cited HPLC and leaves the same settings on the lab's other systems is narrower than what FDA describes. The CAPA software comparison covers tools that track such a plan.
Other data integrity guidance you will be asked about
US drug firms that also supply Europe, or that are audited by European customers, meet three more texts. They cover the same ground as FDA's Q&A, with a different reach and their own wording.
Scroll sideways for every column
| Text | Date | What it covers |
|---|---|---|
| PIC/S PI 041-1 | 1 July 2021 | GMP and GDP data management and integrity; the source of the ALCOA+ list (Complete, Consistent, Enduring, Available) |
| MHRA, Guidance on GxP data integrity | Published 9 March 2018, updated 27 September 2021 | UK guidance across GLP, GCP, GMP, GDP and pharmacovigilance |
| EU GMP Annex 11, Computerised Systems | January 2011 text, in operation since 30 June 2011 | EU GMP computerised systems: risk-based audit trails that are regularly reviewed, and access to data for the retention period. A revision was consulted on in 2025; the 2011 text remains the one in force |
The practical difference is reach. FDA's Q&A is drug CGMP only; MHRA's guidance spans GLP to pharmacovigilance, and PIC/S adds the four ALCOA+ attributes FDA does not list. Where Annex 11 applies, it asks for audit trails “based on a risk assessment” and their regular review, both covered in the guide to EU Annex 11.
FDA's seven questions, as a gap check
- Complete
- “Are controls in place to ensure that data is complete?” Q2, Q12, Q14.
- At the time
- “Are activities documented at the time of performance?” Q12.
- Attributable
- “Are activities attributable to a specific individual?” Q5, Q11.
- Authorized
- “Can only authorized individuals make changes to records?” Q4, Q6.
- Changes recorded
- “Is there a record of changes to data?” Q1.c, Q12.
- Reviewed
- “Are records reviewed for accuracy, completeness, and compliance with established standards?” Q7, Q8, Q10.
- Kept
- “Are data maintained securely from data creation through disposition after the record's retention period?” Q1.e, Q9.
Questions
Is FDA's data integrity guidance legally binding?
No. Every page carries “Contains Nonbinding Recommendations”, and FDA says that in its guidances “should” means “suggested or recommended, but not required.” The answers quote regulations, though. Where an answer says “must” and cites § 211.68(b) or § 211.180, the duty comes from 21 CFR Part 211, and that part is enforceable.
Is there a 2020, 2022 or newer version?
Not of the drug CGMP Q&A. FDA's guidance list, read 2026-10-28, shows the December 2018 text as final, and its page says content current as of 12/13/2018. The newer FDA document with data integrity in its title is a different one: the April 2024 draft on bioavailability and bioequivalence studies, which FDA marks “Not for implementation”.
Does it apply to medical device makers or GLP labs?
It was written for drug CGMP under parts 210, 211 and 212, biologics included. Device makers answer to the QMSR in 21 CFR 820, and GLP labs to Part 58, which has its own rule on changes to automated data (§ 58.130(e)). Neither is bound by this Q&A, but its definitions are a common reference in both. What GxP covers sets the rule sets side by side.
Does FDA require ALCOA+?
FDA's Q&A says ALCOA: attributable, legible, contemporaneously recorded, original or a true copy, and accurate. The four added attributes of ALCOA+ come from PIC/S PI 041-1 (2021), not from FDA. Most quality systems use the longer list anyway; the ALCOA+ guide takes each attribute in turn.
How does it relate to 21 CFR Part 11?
The Q&A says electronic signature and record-keeping requirements “are laid out in 21 CFR part 11” and points to FDA's 2003 Scope and Application guidance for how FDA applies them. It uses Part 11 once in an answer: Q11 relies on § 11.2(a) to let an e-signature stand in for a handwritten one. Part 11 decides how an electronic record and signature must be controlled; the Q&A explains what drug CGMP expects of the data in them.
Where does FDA want data integrity concerns reported?
Q15 invites reports of suspected data integrity issues to DrugInfo@fda.hhs.gov, with “CGMP data integrity” in the subject line. Inside a company, the same answer says a tip is investigated under the CGMP quality system, never handled informally.
Sources
Guidance quoted from FDA; regulation text from the eCFR; EU, UK and PIC/S texts from their publishers. General information, not regulatory advice.
- Data Integrity and Compliance With Drug CGMP: Questions and Answers, Guidance for Industry (December 2018), page and PDF, FDAread 2026-10-28
- Data Integrity and Compliance With Drug CGMP: Questions and Answers; Guidance for Industry; Availability, 83 FR 64132 (December 13, 2018), Federal Registerread 2026-10-28
- Data Integrity for In Vivo Bioavailability and Bioequivalence Studies (draft guidance, April 2024), FDAread 2026-10-28
- Part 11, Electronic Records; Electronic Signatures — Scope and Application (2003 guidance), FDAread 2026-10-22
- Electronic Systems, Electronic Records, and Electronic Signatures in Clinical Investigations: Questions and Answers (October 2024), FDAread 2026-10-22
- 21 CFR Part 211, CGMP for Finished Pharmaceuticals, eCFRread 2026-10-22
- 21 CFR Part 58, Good Laboratory Practice for Nonclinical Laboratory Studies (§ 58.130(e)), eCFRread 2026-10-22
- PI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments (1 July 2021), PIC/Sread 2026-10-22
- Guidance on GxP data integrity (March 2018, updated September 2021), MHRAread 2026-10-22
- EudraLex Volume 4, Annex 11: Computerised Systems (2011), European Commissionread 2026-10-22