CAPA form template

A free CAPA form template for QC labs, drug makers and device makers: problem, containment, root cause with a 5-whys chain, corrective and preventive actions with owners and dates, an effectiveness check, and two signatures. Copy it or print it as a controlled record. Running CAPAs in software instead? See our Part 11 compliant CAPA software comparison.

What a CAPA form records

A corrective and preventive action form is the record that carries one quality problem from the event to a verified fix: the problem, what was done to contain it, the investigation and root cause, the actions with owners and dates, a planned effectiveness check, and a signed closure. Device makers keep it under the FDA QMSR, which brought ISO 13485 into 21 CFR 820; drug makers keep it to meet the investigation and quality-unit duties of 21 CFR 211.

The form above is built around the deviation that most often turns into a CAPA in a QC lab. Raise the deviation itself in your deviation system first; our deviation management software comparison shows which tools carry the link from a deviation to its CAPA.

How to use this CAPA form

  1. 01

    Pick who the CAPA is for

    Device maker or drug maker. The toggle changes the governing requirement printed in the header and the wording of the extent field.

  2. 02

    Link the source

    Every CAPA starts from a record: a deviation, a complaint, an audit finding or a trend report. Put its number in the header so either record leads to the other.

  3. 03

    Write the problem, then contain it

    Facts and numbers first. Containment is what you did to the product and the material this week; it is not the CAPA.

  4. 04

    Work the why chain to a cause you can remove

    Each answer becomes the next question. Stop when the answer is something a procedure, a system or a design change can remove.

  5. 05

    Plan actions with owners and dates

    Corrective actions remove the cause found. Preventive actions take the same fix to places where the problem has not happened yet.

  6. 06

    Set the effectiveness criteria before the plan is signed

    A number, a window and the data you will read. The form flags a check dated before the last action is due.

  7. 07

    Sign twice, for two different things

    The first signature approves the plan. The second, weeks or months later, verifies the result against the criteria and closes the CAPA.

Print it from the Record tab for a paper CAPA signed in ink, or Copy it as plain text into your quality system. The record checks above the form list what a reviewer will look for before each signature.

Worked example: an expired reference standard

The pre-filled CAPA follows a reference standard used in six release assays after its retest date. It is a lab problem with a system cause, which is why it shows the gap between containment and a real corrective action. Here is how its key entries are written.

Key entries of the worked example and why each is written that way
FieldEntryWhy it is written this way
Problem statementRS-118 lot 4471 used in 6 sequences after its 2026-05-27 retest date; 4 lots reported, 2 releasedCounts and dates only. A reviewer can check every number against the data system.
ContainmentLot quarantined, unreleased lots on hold, 6 sequences re-run with an in-date lotThese deal with the product. None of them stops it happening again, so none of them is listed as an action.
Why 1 to 5Label misread, label layout, no system check, spreadsheet not at the bench, inventory left out of the LIMSThe chain moves from the analyst to the system. Stopping at why 1 would have ended in retraining.
ExtentEvery RS-118 sequence since the retest date; all 31 standards checkedThe drug rule asks for other batches and products that may be associated, whether or not a batch has shipped.
C1LIMS hard block on use after the retest date, under change control CC-2026-033Removes the cause at the point of use. The change control number ties the system change to this CAPA.
P1Same block on working standards, reagents and HPLC columnsPreventive: no reagent has failed yet, but the same gap exists there.
CriteriaZero out-of-date standards and zero overrides in the 60 days after the block goes liveWritten before the check, measured from the LIMS report and audit trail, so the result can be checked by someone else.
SignaturesApproval of the plan (Head of QA); review of effectiveness and closure (QA Manager)Two acts, two meanings, two dates. Neither signer owns the CAPA.

Writing each part so it holds up

Containment is a correction, not the CAPA

FDA draws the line in the QMSR preamble: a correction “may also refer to scrap, repair, rework, or adjustment and relates to eliminating a nonconformity, whereas ‘corrective action’ relates to the elimination of the cause of nonconformity and to prevent recurrence.” Quarantine, holds and re-tests go in section 2. Section 4 holds only what removes the cause.

Preventive means somewhere it has not happened yet

FDA kept corrective and preventive action as two clauses when it adopted ISO 13485, and said its earlier reading of preventive action “did not apply solely to preventing recurrence of quality problems.” In the example, the expiry block on reagents and columns is preventive: none has failed, but the same gap is there.

Size the effort to the risk

For devices FDA expects the action to be “appropriate to the magnitude of the problem and commensurate with the risks encountered.” For drugs, a CAPA follows from § 211.192: a discrepancy is “thoroughly investigated, whether or not the batch has already been distributed”, and the written record “shall include the conclusions and followup.” Deviations from a written procedure are “recorded and justified” (§ 211.100(b)).

A weak root cause

“Analyst error” closed with retraining. It names who, not why, and the effectiveness check has nothing to measure. Keep asking why until the answer is a label, a screen, a step or a missing system check. Then record the retraining in the training record template as one action among others.

Effectiveness is decided before it is measured

The device rule, in FDA's words: manufacturers “must verify or validate corrective and preventive actions to ensure that such actions are effective and do not adversely affect the finished device.” FDA's Q10 guidance says the same for drug manufacturing: “the effectiveness of the actions should be evaluated.” Write the criteria before the plan is signed, so the result cannot be fitted to the data.

The two signatures, and when Part 11 applies

The form carries two signature blocks because they record different acts. The first approves the investigation, root cause and plan. The second, after the check, verifies that the result met the criteria and closes the CAPA. § 11.50(a) asks each electronic signature to show the printed name, the date and time, and “the meaning (such as review, approval, responsibility, or authorship)”. One signature cannot carry both meanings. For a drug maker the quality control unit has the authority to review records “to assure that no errors have occurred or, if errors have occurred, that they have been fully investigated” (§ 211.22(a)). For devices, FDA reads ISO 13485's “approved” as a signature and date, and accepts electronic signatures that meet its requirements.

  • Printed and signed in ink: the paper is the record. FDA's 2003 guidance says that when paper printouts meet the predicate rules and are relied on, using a computer to make them does not trigger Part 11.
  • Signed in a quality system: both signatures fall under Part 11. The name, date and time and meaning must appear on every display and printout (§ 11.50(b)), each signature is linked to this CAPA so it cannot be copied to another (§ 11.70), and every later edit to the root cause is trailed without hiding the first entry (§ 11.10(e)). Test your system's output with the signature manifestation check and its trail with the audit trail review checklist.

Inspection risk

An effectiveness check signed the same day the last action closed. No data can exist yet, and the dates on the record show it. The form flags a check dated on or before the last due date.

When a form is no longer enough

A paper or spreadsheet CAPA log works for a handful a year. Past that, the gaps are links and dates: a deviation with no CAPA number, an action past due with no one told, an effectiveness check nobody scheduled. Our comparison of Part 11 compliant CAPA software reads each vendor against the signature and audit-trail rows above, and the eQMS comparison covers suites where CAPA, deviations and change control share one record.

Where the rule says so